Comparison Between Nephelometry &Turbidimetry : Question of Old Exams GPAT, GATE, Pharmacist Recruitment
Comparison Between Nephelometry & Turbidimetry :-
1. Principal :-
Nephelometry:- it is work on light scattered. It is similar to fluorimetry.
Turbidimetry :- It is work on light transmission. It is similar to colorimetery.
2. Sensitivity :-
Nephelometry:- it is more sensitive because it is used for low concentration suspension.( <100 mg/ litre).
Turbidimetry :- it is less sensitive.
3. Effect of concentration on intensity :-
Nephelometry:- linear realtion ship between concentration and intensity of the light.
Turbidimetry :- Relationship between concentration and intensity of the light are depends on the below equation :-
log Io/I =kbc
Where,
Io = Intensity of incident light
I = intensity of transmitted light
K = Turbidity co efficient
C = concentration of particle
b = pathlength
4. Effect of wavelength on intensity :-
Nephelometry:- wavelength is not much important white light is used.
Turbidimetry :- wavelength play important role relations between wavelength and turbidity is given by following equation :-
T= S/λt
Where,
T = turbidity
S= constant for a given system
λ = wavelength
t = it’s value depends on particle size.
5. Filter :-
Nephelometry:- visible filter are used as secondary filter.
Turbidimetry :- Blue filter is used or adjusted at 530 nm.
Application of Nephelometry & Turbidimetry :-
- Analysis of inorganic compound.
- Analysis of organic compound.
- Analysis of the water purity.
- Analysis of the air and water pollutants.
- Determination of impurity and particularly matter in pharmaceutical aersol, injection, suspension and other liquid preparation.
MCQ
1. Nephelometry is similar to
A. fluorimetry
B. Colorimetery
C. UV-VISIBLE
D. NMR
2. Turbidimetry is similar to
A. fluorimetry
B. Colorimetery
C. UV-VISIBLE
D. NMR
3. Which filter are used as secondary filter in Nephelometry?
A. Visible filter
B. Absorption filter
C. A and B
D. None of the above
4. Which is filter are used in Turbidimetry ?
A. Blue filter
B. Visible filter
C. Absorption filter
D. All of the above
5. Which sentence is true about Nephelometry ?
A. It is less sensitive.
B. Wavelength is more important.
C. Intensity of the light and concentration graph is linear.
D. It is not used in analysis of the collodial systems.
6. Which sentence is True about Turbidimetry ?
A. It is more sensitive.
B. Wavelength is not important.
C.Intensity of the light and concentration graph is linear.
D. It is similar to colorimetery .
7. Which sentence is false about Nephelometry ?
A. It is more sensitive (>100mg/litre)
B. Wavelength is not important.
C. Intensity of the light and concentration graph is linear.
D. It is not used in analysis of the collodial systems.
8.Which sentence is false about Turbidimetry ?
A. It is more sensitive.
B. Wavelength is important according to the equation.
C. intensity of the light and concentration realtion ship is according to the equation.
D. It is similar to colorimetery .
Answer key :-
1. A
2. B
3. A
4. A
5. C
6. D
7. C
8. A